Vertex Standard VX-4000 Bedienerhandbuch Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
F
U
S
E
3
0
A
B
A
C
K
U
P
I
N
P
U
T
D
C
1
0
.
8
-
1
3
.
2
V
3
0
A
P
O
W
E
R
O
N
O
F
F
Installation
AC Power Connection / Voltage Confirmation
The power supply in the BSC-5000 is capable of operation from
100 ~ 235 VAC at 50 or 60 Hz. The power supply in the BSC-
5000 does not require any transformer re-wiring, nor any chang-
ing of a switch position; the power supply will operate from ei-
ther 220 or 117 Volt line voltages without configuration changes.
This should be indicated by a label near the AC jack on the rear
panel. If no label is present, or if the AC voltage on the label is
different from the local AC line voltage, please examine the fuse
which is located near the AC jack for 100-117 V, use an 8 A fuse;
for 200-240 V, use a 6.3 A fuse.
Backup Power Supply
For uninterrupted operation during power failures, a 12 Volt
rechargeble type battery (55-Ah or more recommended) may be
connected to the BACKUP terminal posts on the rear panel.
When AC power is interrupted, the automatic power control cir-
cuit will automatically switch the BSC-5000 to the backup bat-
tery, and operation will not be interrupted.
After prolonged operation from the battery, it should be discon-
nected from the BSC-5000 and recharged separately before re-
connecting, as the trickle charge is not sufficient for recharging
a completely discharged battery.
Never reapply AC power to the BSC-5000 with a discharged
battery connected, as the DC start-up current can damage the
BSC-5000 and battery.
Lithium Battery Replacement
The BSC-5000's clock is run by a lithium battery. When the dis-
play becomes weak or clock operation ceases, it is time to re-
place the battery. The 3-Volt Lithium battery (P/N Q9000564) is
located on the top circuit board (RELAY Unit) of the BSC-5000.
1. Remove the 8 screws affixing the top cover, then remove the
top cover. Using your finger, slide the battery inward (you
will feel slight pressure by the mounting spring) then slightly
pry it up and outward so that it ejects freely through the
slots in the battery holder.
Transceiver Installation
The VX-4000/5500/6000 Mobile transceivers are all compatible
with the BSC-5000. Installation is simple and straightforward.
1. Remove the 17 screws affixing the top and bottom covers of
the BSC-5000, then remove the covers.
2. Turn the BSC-5000 upside down.
3. Use a sharp knife to make an "X" cut in the rubber cap, so as
to allow insertion of the antenna's coaxial cable.
5. Transceiver installation is now complete. Replace the top and
bottom covers.
Option Installation
Cooling Fan (FAN-1) Installation
1. Remove the 8 screws affixing the top cover of BSC-5000, then
remove the top cover.
2. Carefully note the battery polarity;
the positive (+) side (which includes
the battery model number) must be
facing up. Install the replacement
battery with the same polarity as when you removed it.
The Lithium Battery must be recycled or disposed of properly.
2. Pass the Cooling Fan's cable through the ventilation slot,
and connect it to the 2-pin jack (J1012) on the RELAY Unit.
3. Mount the Cooling Fan to the rear panel of the BSC-5000
using the supplied screws.
VEGA Tone-Remote Adapter Installation
1. Remove the 8 screws affixing the top cover of BSC-5000, then
remove the top cover.
2. Remove the panel from the VEGA 1223C Series Tone-Re-
mote Adapter and the VEGA 1224 Expansion Module.
3. Connect the VEGA 1223C Series Tone-Remote Adapter to
the Edge Connector which has the 5-pin Connector Cable,
then connect the VEGA 1224 Expansion Module to the other
Edge Connector.
4. Mount the VEGA 1223C Series Tone-Remote Adapter and
VEGA 1224 Expansion Module onto the chassis of the BSC-
5000, using the eight screws supplied with the CT-103.
5. Connect the 5-pin Connector Cable to J1014 on the RELAY
Unit, and connect the 12-pin Connector to J1013 on the RE-
LAY Unit.
6. Mount the Modular Jack on the rear panel of the BSC-5000
using the two supplied screws. You may choose either a 2-
wire or 4-wire Modular Jack.
7. VEGA Tone-Remote Adapter installation is now complete.
Replace the top cover.
J1012
to Cooling Fan
RELAY Unit
Antenna Coaxial Cable
Interface Cable
DC Cable
MIC Cable
Speaker Cable
Mounting Screws
(4 pcs)
VX-6000: Fit mounting screws here.
VX-4000/5000: Fit mounting screws here.
4. Install the transceiver into the compartment on the bottom
side of the BSC-5000, using the four supplied mounting
screws. Then connect the MIC Cable, Speaker Cable, DC
Cable, DSUB 25-pin Accessory Cable, and Antenna Coaxial
Cable to the transceiver.
Important Note: When installing the VX-6000 into the BSC-
5000, be careful to utilize the correct mounting screw loca-
tions (see illustration below). Tighten the screws using pli-
ers when installing a VX-6000.
Also, when installing the VX-6000, be sure to replace the
2-pin DC cable with the supplied 4-pin type.
Typical VX-4000/5500 Installation
Coaxial cable
Rubber Cap
Rubber Cap
Knife
Rubber Cap
¬
¬
FUSE 30A
BACKUP
INPUT
DC 10.8 - 13.2V
30A
POWER
ONOFF
FUSE 30A
BACKUP
INPUT
DC 10.8 - 13.2V
30A
POWER
ONOFF
VEGA
1223C Series
Tone-Remote
Adapter
RELAY-Unit
VEGA Tone-Remote Interface
Cable SET (CT-103)
J1014
J1013
2-WIRE: J1015
4-WIRE: J1016
VEGA
1224 Expan-
sion Module
4. Cooling Fan installation is now complete. Replace the top
cover.
Seitenansicht 1
1 2

Kommentare zu diesen Handbüchern

Keine Kommentare