15VX-1400 OPERATING MANUAL
BASE STATION INSTALLATION
DC Power Connections
For base station installations, Vertex Standard recommends the use of the optional FP-
1030A AC Power Supply. The FP-1030A provides a regulated 13.8 V DC supply at up to
25-Ampere.
Other models of DC power supplies may be used with the VX-1400, but the 13.8 V DC
input voltage, 23-Ampere current capability, and DC cable polarity guidelines described
previously must be strictly followed.
If you are connecting the FP-1030A with the VX-1400 for the first time, before
connecting power check the label in the rear of the FP-1030A which indicates the
AC mains voltage for which the supply is currently set.
CAUTION! Permanent damage can result if improper supply voltage is applied to this trans-
ceiver. Your warranty does not cover damage caused by application of AC, reversed polar-
ity DC, or DC outside of the specified range of 13.8 V ±15%. If using a power supply
other than the FP-1030A, ensure that the DC supply connector to the transceiver matches
the VX-1400 wiring configuration. Other manufacturers may utilize power supplies with
a physically matched connector that is wired differently; this will cause serious damage to
the VX-1400 transceiver!
INSTALLATION
Supplied DC Cable
VA
005510 2015 3020 40
CONTINUOUS CURRENT 25A
OVERLOAD
POWER
ON
OFF
FP-1030A
VX-1400
RED BLACK
FUSE: 25A